5
This installation is used to dehumidify a
whole house and also a separate conditioned
space like a finished basement. Two dampers
are installed, one normally-closed damper
(6508) is installed in the branch leading from
the dehumidifier to the supply duct, and one
normally-open damper (6608) is installed in
the branch leading from the dehumidifier back
to the conditioned space. For convenience, a
basement kit (4522), which includes a
normally-closed damper (6508), a normally-open
damper (6608), and a 40VA, 24 VAC plug in
transformer (8027) can be ordered.
When the HVAC blower and the dehumidifier
are on, the dampers will energize and the
dehumidifier will operate in a whole-house
mode (Figure 4).
When the HVAC blower is off, the dampers
will be de-energized and the dehumidifier will
operate in a localized mode (Figure 5).
Note: The dampers will also be de-energized
when the dehumidifier is off preventing
backflow of air when only the HVAC blower
is on.
WHOLE-HOUSE, WITH LOCALIZED OPTION FOR CONDITIONED SPACE
In this configuration, the dehumidifier will automatically switch between whole-house dehumidification when the HVAC equipment
is on, and localized dehumidification when the HVAC equipment is off.